System plug not included.
.


Detail view
S300 Mini Standard, Laser scanner
At a glance
- Very compact design
- Triple field sets (1 protective field and 2 warning fields)
- 1 field set
- 1 monitoring case
- 270° scan angle
- 2 m protective field range
- Easy to operate
- Vertical and horizontal protection
- Simple integration thanks to very compact design
- Reduction of downtimes and brake wear thanks to triple field function
- Unbeatable cost-effectiveness - 270° scanning angle allows all-round protection with only two scanners
- Flexible safety solution for individual application adjustment
- Easy to manage, reducing costs and work time
Applications
| Hazardous area protection (vertical): | + |
| Access protection (vertical): | + |
| Hazardous area protection (horizontal): | + |
Functions
| Static control outputs for switching between warning fields: | - |
| Incremental encoder inputs: | - |
| External device monitoring: | + |
| Integrated configuration memory: | - |
| Reflector mark detection: | - |
| Expanded measured data output: | - |
| Safe device communication via EFI/SDL: | - |
Technical data
| Laser protection class: | 1 (CFR 1040.10 and 1040.11, CDRH 21, IEC 60825-1) |
| Enclosure rating: | IP 65 (EN 60529) |
| Protection class: | III (EN 50178 and EN 60950) |
| Type: | Type 3 (EN 61496-1) |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
| Category: | Category 3 (EN ISO 13849) |
| Performance level: | PL d (EN ISO 13849) |
| PFHd: | 4.0 * 1E-08 |
| TM (Mission Time): | 20 a |
| Ambient operating temperature from ... to: | -10 °C ... 50 °C |
| Dimensions (W x H x D): | 102 mm x 116 mm x 105 mm |
| Weight: | 0.8 kg, without connecting cables |
| Scan angle: | 270 ° |
| Protective field range: | 2 m |
| Maximum warning field range: | 8 m |
| Number of field sets: | 1, triple field set with 1 protective field and 2 warning fields each |
| Number of monitoring cases: | 1 |
| Response time: | 80 ms |
| Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, selectable |
| Distance measuring range: | 30 m |
| Number of multiple samplings: | Configurable via CDS 2 ... 16 |
| Electrical connection: | Connecting cable with round plug connector |
| Supply voltage: | 16.8 V DC, 24 V DC, 30 V DC |
| Number of universal I/Os: | 2 |
| Number of EDM inputs: | 1 1) |
| Number of reset-/restart inputs: | 1 2) |
| Number of stand-by inputs: | 1 3) |
| Number of safe outputs: | 2, Safety outputs (OSSD) |
| Number of warning field outputs: | 2 4) |
| Configuration and diagnostics interface: | RS-232 |
Delivery contents
- Sensor
- CD-ROM with Manuals and Software "Configuration and Diagnostic Software" CDS
System plug not included.
Recommended Accessories
| S200 | |
|---|---|
| SICK-2032807 | System plug |
Download
Datasheet
Product Information S300-Mini
Product information for: S300 Mini Standard Safety Laserscanner
Publishing date (date of last technical specification): 2011-06-15
Shipping weight: 2,10 kg
Manufacturer: SICK Brand: SICK
Article number: SICK-1050932
The article S300 Mini Standard Safety Laserscanner is part of the following categories:
Customer Groups > System Integrators > Sick Laser-scanner
Customer Groups > Industry > Safety > Safety Laser Scanners
.