Availability

Not in stock. We will obtain the article for you.

Estimated manufacturer's time of delivery: 2-3 days
updated: 16.11.2012


Request for quotation

Phone +49 941 / 94 59 280
Fax +49 941 / 94 59 289
E-mail: Contact form



About SICK




More of this brand

SICK.jpg
You are here: Main page › Components › SICK-1044369.shtml

Detail view

Dx50

At a glance

  • HDDM technology provides the best reliability, immunity to ambient light and price/performance ratio
  • Reliable measurement and detection up to 10 m
  • Wide choice of models: 4 mA ... 20 mA or 0 .V .. 10 V; PNP or NPN and laser Class 1 or 2
  • High switching repeatability (± 2.5 mm)
  • Display with intuitive operating concept
  • Tough die-cast zinc metal housing
  • Wide operating temperature range from -30 °C to +65 °C
  • Wide measurement range allows easy and fast integration in any production environment
  • Intuitive setup via display or remote teach reduces installation time and costs
  • Widest temperature range allows for outdoor use without additional cooling or heating accessories
  • Immune to any type of ambient light - allows for use in optically challenging environments
  • Increased process stability is achieved thanks to the small black/white shift
  • Metal housing withstands harsh environments, saving replacement costs
  • Low investment costs and high performance guarantee quick return on investment
  • Dx50 family is based on a common platform, which offers multiple performance levels, making it easy to accommodate future changes

Performance

Measuring range 90 % remision: 200 ... 10,000 mm
Measuring range 18 % remission: 200 ... 6,500 mm
Measuring range 6 % remission: 200 ... 4,000 mm
Resolution 6 ... 90 %: 1 mm
Repeatability 6 ... 90% remission 5 mm 2.5 mm 1) 2)
Accuracy 90 % remission: ± 10 mm
Response time 20 ms / 30 ms 3)
Output rate: 4 ms
Light source red laser 4)
Laser protection class: 2 (EN 60 825-1)
Typ. light spot size (distance): 15 mm x 15 mm (10 m)
Additional features: Set moving averaging: fast/slow, Switching mode: Distance to object (DtO), Teach-in of analog output, Teach in of switching outputs, Scaling of analog outputs, Set levels of switching outputs, Set hysterisis, Switching output invertable, Multi functional input: laser off, external teach, not active, Switch off display, Reset to factory default, Lock user interface, Invertable analog output

Interfaces

Analog current outputs (max. load): 1x 4 ... 20 mA (= 300 O)
Resolution analog outputs: 16 Bit
Switching hysteresis: 10 mm ... 1,000 mm
Switching outputs (max. output current) 1 x PNP (100 mA) 1) 2)
Multi functional inputs 1 x PNP 3) 4)

Mechanics/electronics

Supply voltage VS DC 10 V ... 30 V 1)
Ripple = 5 Vpp 2)
Power consumption = 2.1 W 3)
Initialization time: = 250 ms
Warm up time: = 15 min
Typ. weight without cable: 200 g
Housing material: Die-cast zinc housing (ZNAL4CU1) Plastic front window
Connection type: Connector M12, 5-pin
Indication: 2 x LED, LC Display

Ambient data

Enclosure rating: IP 65
Protection class: III
Ambient temperature: Operation: -30 ... 65 °C Storage: -40 ... 75 °C
Max. rel. humidity (not condensing): = 95 %
Typ. temperature drift: 0.25 mm/K
Vibration resistance: EN 60068-2-6 / -2-64
Shock resistance: EN 60068-2-27 / -2-29
Average service life laser (MTTF at 25 °C): 100,000 h


Product information for: DT50 Mid Range Distance Sensor

Publishing date (date of last technical specification): 2007-01-01
Shipping weight: 400 g
Manufacturer: SICK Brand: SICK
Article number: SICK-1044369



The article DT50 Mid Range Distance Sensor is part of the following categories:

Customer Groups > Industry > Distance measurement

SICK-1022938.jpg
SICK
DT200 Mid Range Distance Sensor
Request for quotation
SICK-1044369.jpg
SICK
DT50 Mid Range Distance Sensor
Request for quotation

.

Contact us










* These fields are mandatory.

Top of page | Main page
© Manu Systems AG, 2003 - 2012 | About Us | All topics | Help | Imprint

PayPal.gif